Modular Valves
D
D-50
Counter Balance
Modular Valve
40 to 300
rr
/min
14MPa
Features
q
This modular valve is used to control
actuator back pressure and for other
pressure control valve applications.
w
Pressure adjustment is possible across
a wide range, from 0.25 to 14MPa {2.5
to 143kgf/cm
2
}.
e
Maximum Operating Pressure: 25,
35MPa {255, 357kgf/cm
2
}
Specifications
Model No.
Nominal
Diameter
(Size)
Maximum Working
Pressure
MPa{kgf/cm
2
}
Maximum Flow
Rate
r/min
Pressure Adjustment
Range
MPa{kgf/cm
2
}
Weight
kg
Gasket Surface
Dimensions
OCQ-G01-A11-20
A12
1/8 25{255} 40
0.8 to 7{ 8.2 to 71.4}
3.5 to 14{35.7 to 143}
1.1
ISO 4401-03-02-0-94
OCQ-G01-B11-20
B12
0.8 to 7{ 8.2 to 71.4}
3.5 to 14{35.7 to 143}
1.1
OCQ-G03-A1A-J50
A1C
A1E
3/8 25{255} 80
0.25 to 0.85{ 2.5 to 8.7}
0.85 to 3.5{ 8.7 to 35.7}
3.5 to 14{35.7 to 143}
3.5
ISO 4401-05-04-0-94
OCQ-G03-B1A-J50
B1C
B1E
0.25 to 0.85{ 2.5 to 8.7}
0.85 to 3.5{ 8.7 to 35.7}
3.5 to 14{35.7 to 143}
3.5
OQH-G04-A1A-10
A1C
A1E
1/2 35{357} 300
0.25 to 0.85{ 2.5 to 8.7}
0.5 to 3.5{ 5.1 to 35.7}
2.0 to 14{20.4 to 143}
8.0
ISO 4401-07-06-0-94
OQH-G04-B1A-10
B1C
B1E
0.25 to 0.85{ 2.5 to 8.7}
0.5 to 3.5{ 5.1 to 35.7}
2.0 to 14{20.4 to 143}
8.0
zThe pressure adjustment range is
expressed in terms of cracking
pressure.
xRun tank port piping directly to the
tank, and ensure that back pres-
sure is as small as possible.
cNote that a sub plate and installa-
tion bolts are not included. See
pages D-90 through D-95 if these
items are required.
v04 series modular valves do not
have an L (DR
2) drain port, so they
cannot be used in combination with
pressure center type solenoid
valves (D).
J50–(K)–A1B–03G–OCQ
Pressure adjustment range
Type 1 Internal pilot
Internal drain
Control port A: A port
B: B port
Nominal diameter (size) 01, 03
Mounting method G: Gasket type
Counter balance modular valve
Design number
Note: For 03 size, relationship between mounting bolts and design number is
indicated as J50: M6, 50 : M8.
Auxiliary symbol K: With handle (01, 03 size)